节点文献
药品中残留钯的电感耦合等离子体发射光谱法测定
Determination of Residual Palladium in Medicine by Inductively Coupled Plasma-Atomic Emission Spectrometry
【摘要】 采用电感耦合等离子体发射光谱法测定药品中残留的钯。检测波长 34 0 .45 8nm,平均回收率为 97.2 % ,RSD为 3.5 % ,最低检出限为 0 .0 4μg/ ml,本方法干扰少 ,操作简便快速。
【Abstract】 Inductively coupled plasma atomic emission spectrometry was employed for determination of residual palladium in medicine. The detective wavelength was 340.458 nm. The average recovery was 97.2%, the RSD was 3.5%, and the limit of detection was 0.04 μg/ml. This method was of less interference and simple to operate.
【关键词】 药品;
残留;
钯;
电感耦合等离子体发射光谱法;
测定;
【Key words】 medicine; residue; palladium; inductively coupled plasma atomic emission spectrometry; determination;
【Key words】 medicine; residue; palladium; inductively coupled plasma atomic emission spectrometry; determination;
- 【文献出处】 中国医药工业杂志 ,CHINESE JOURNAL OF PHARMACEUTICALS , 编辑部邮箱 ,2000年09期
- 【分类号】R927
- 【被引频次】9
- 【下载频次】159