【摘要】 从燃用煤质、运行情况等多方面分析耒阳电厂 670t/h燃用当地低挥发分无烟煤锅炉燃烧效率低的原因,对 设备进行一系列技术改造和运行调整,逐步提高了锅炉燃烧效率,并提出进一步改进的措施与建议。
【Abstract】 The causes for low combustion efficiency of 670 t/h local low volatile anthracite-fired boilers in Leiyang Power Plant were analyzed in aspects of fired coal quality and operation situation etc.A series of technical retrofits and operation adjustments on equipment were carried out,with the combustion efficiency of boilers gradually raised,and the further improvement measures and proposals were put forward.