节点文献
应用Amplatzer堵闭器经心导管关闭动脉导管未闭的体会
Experience of transcatheter closure of patent ductus arteriosus using Amplatzer device
【摘要】 目的 探讨Amplater封闭器关闭动脉导管 (PDA)的临床效果。 方法 应用Amplater堵闭器共堵闭 6例PDA。PDA于肺动脉开口处的最窄直径 3~ 4.5cm(平均 3.7cm)。结果 均获成功。 3~ 6个月随访堵闭器无移位 ,无残余分流。结论 应用Amplater堵闭器关闭大、中型PDA效果良好 ,安全可靠 ,血管损伤小
【Abstract】 Objective To appraise the clinical results of Amplatzer device in closure of PDA.Method We used Amplatzer divice in 6 cases, the diameters of narrowest part of PDA near the pulmonary artery were 3~4.5mm (average 3.7 mm). Results All of the patients were successful. Conclusions In moderate and large sized patent ductus, using Amplatzer device to close the patent ductus is reliable and safe, the damage of vascular endothelium is minimal. The cost is rather expansive and thus not extensively used.
- 【文献出处】 介入放射学杂志 ,JOURNAL OF INTERVENTIONAL RADIOLOGY , 编辑部邮箱 ,2000年02期
- 【分类号】R654.2
- 【被引频次】5
- 【下载频次】15