光照度计偏振特性的实验研究
Research on Polarization Dependence of Illuminance Meter
【摘要】 介绍了光源偏振度的测量和消偏振的方法以及照度计偏振误差的概念。测量了实验室用的三支灯的偏振度及两台照度计的偏振误差。测量结果表明,光源偏振度均小于10 % ,当光垂直入射时对照度计的影响是非常小的。
【Abstract】 The measurement method of the polarization grade for the source and depolarization and the concept of the polarization error for the illuminance meter are described. The polarization grade of three lamps for the laboratory and the polarization error of two illuminance meters are measured. The measuring results evince the polarization grade of the source is 10% at most, and the meters are not polarization sensitive to normal incidence.
【关键词】 偏振度;
偏振误差;
照度计;
自然光;
偏振光;
【Key words】 Polarization grade; Polarization error; Illuminance meter; Perfectly unpolarization light; Polarization light;
【Key words】 Polarization grade; Polarization error; Illuminance meter; Perfectly unpolarization light; Polarization light;
- 【文献出处】 计量学报 ,ACTA METROLOGICA SINICA , 编辑部邮箱 ,2000年01期
- 【分类号】TB96
- 【被引频次】3
- 【下载频次】124