节点文献

撞击法监测室内空气微生物稳定性研究

Study on the Stability of Impact Assay for Detection of Microorganism of Indoor Air

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李燕

【Author】 LI YanCentral Sanitation and Anti-epidemic Station, Liuzhou Railway Bureau, 545007

【机构】 广西柳州铁路局中心卫生防疫站!545007

【摘要】 为探讨撞击法监测室内空气微生物的稳定性 ,使用 JWL - B型多功能空气微生物监测仪对招待所、文化娱乐场所、理发美容室中 11个场所分别进行 2 min、 4min监测 ,结果显示 :在同一个环境下采样时间不论 2 min还是 4min,其测定值差异无显著性 (t=1.85 4,P>0 .0 5 ) ,说明用撞击法监测室内空气微生物在所测定的时间内有较好的稳定性

【Abstract】 To explore the stability of impact assay for determination of microorganism in indoor air,the compa- risons of continued sampling times of 2-minute and 4-minute for monitoring on microorganism of indoor air were carried out with JWL-ⅡB multi-functiom air microorganison monitor in 11 hotels, public places of entertainment, barbar shops and beauty shops The results showed that, under a same environmental condition, there was no significant differences between the data obtained by 2-minute monitoring and 4-minute monitoring (t=1854, P>005) It indicated that impact assay presented very good stability in detecting the microorganism of indoor air within certain detecting duration

【关键词】 撞击法室内空气微生物
【Key words】 Impact assayIndoor airMicroorganism
  • 【文献出处】 环境与健康杂志 ,Journal of Environment and Health , 编辑部邮箱 ,2000年06期
  • 【分类号】R12
  • 【被引频次】10
  • 【下载频次】154
节点文献中: 

本文链接的文献网络图示:

本文的引文网络