节点文献

热力发电厂炉水低磷处理的实践

Practice of boiler water low phosphate treatment in steam power plants

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 岳长贵刘国树陈秀誉李兴

【Author】 YUE Chang gui 1,LIU Guo shu 1,CHEN Xiu yu 1,LI Xing 2 (1.Tianjin First Steam Power Plant,Tianjin 300171,China; 2.Tianjin Electric Power Corporation,Tianjin 300010,China)

【机构】 天津第一热电厂!天津300671天津电力公司发电部!天津300010

【摘要】 介绍了热电厂炉水处理中存在的 pH合格率低、水冷壁沉积率高的问题 ,改进了处理方法 ,由协调磷酸盐处理改为低磷处理 (pH9.4~ 9.6,PO43 - 2~ 3mg/L) ,经过一年的实际应用 ,低磷处理取得成功 ,水汽品质提高 ,沉积率下降 ,腐蚀得到抑制 ,并有较好的经济效益。

【Abstract】 The artical introduces the problems in boiler water treatment in steam power plants. The problems are that pH eligibility is low and that scaling rate of water wall tube is high. they are improving the boiler water treatment,changing from phosphate treatment to low phosphate treatment (pH9.4~9.6,PO 3- 42~3 mg/L).After one year application,the new treatment method has had success. The water and steam quality eligibility gets higher,scaling rate of water wall tube gets lower. The corrosion of water wall tube gets inhibited and gets better economic benefit.

【关键词】 热电厂炉水处理腐蚀磷酸盐
【Key words】 steam power plantboiler water treatmeatcorrosionphosphate
  • 【文献出处】 工业水处理 ,INDUSTRIAL WATER TREATMENT , 编辑部邮箱 ,2000年10期
  • 【分类号】TM621.8
  • 【被引频次】3
  • 【下载频次】65