节点文献
ICP-AES法直接测定地热温泉水样中的钾、钠、钙、镁、硅、锂、硼的研究
The Research on the Determination of K,Na,Ca,Mg,Si,Li,B in the Samples of Hot Spring by ICP-AES Method
【摘要】 采用顺序扫描式 ICP光谱仪 ,直接测定了地热温泉水样中的 7种元素 ,并对最佳测试条件的选择进行了探讨。方法简便、快速、准确 ,检出限及精密度均可满足分析要求。
【Abstract】 This method for direct determination of 7 elements in the samples of hot spring by using Atom Scan 16 spequential ICP spectrometer is studied. And the selection about optima conditions had also been researched.The method was simple,quick,and accurate .The detection limit and precision are very satisfactory.
- 【文献出处】 光谱实验室 ,CHINESE JOURNAL OF SPECTROSCOPY LABORATORY , 编辑部邮箱 ,2000年06期
- 【分类号】O657.31
- 【被引频次】27
- 【下载频次】438