耐受电流暂态分量影响的新型差动保护

A NEW DIFFERENTIAL PROTECTION OF TRANSMISSION LINE WITH STRONG IMMUNITY FROM NOISE IN CURRENT TRANSIENT COMPONENT

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 袁荣湘陈德树张哲

【Author】 Yuan Rongxiang. Chen Deshu. Zhang Zhe (Huazhong University ofScience and Technology, Wuhan 430074, China)

【机构】 华中理工大学电力系!武汉430074

【摘要】 提出一种新型差动保护,在时域中对两端电流的故障分量波形进行比较,并且考虑全频域内的信号, 较少受故障期间暂态分量的影响。同电流差动保护相比,该保护可更可靠、快速动作,同时,它对信号的同步要求较低,也较容易实现与整定,能够成为超高压长距离输电线路的主保护

【Abstract】 A new differentialprotection schem e is designed, in which the currentfaultcom ponentw aves in two term inals of the protected transm ission line are com pared in tim e-dom ain, and the w hole inform ation in frequency dom ain is taken into account. Com pared with currentdifferentialprotection, the new protection has better perform ance on resisting the influence oftransientcom ponent, higher reliability and fasterspeed. The dem and for the synchronism ofthe currentis com paratively low . Itfreesfrom thesystem oscillation. Itcan be realized easily and could bethe prim ary protection ofthelong transm ission linesw ith ultra-high-voltage. This projectissupported by the Research Fund forthe DoctoralProgram ofHigherEducation (RFDP) (No.96048723).

【基金】 高等学校博士学科点专项科研基金!资助项目(96048723)
  • 【文献出处】 电力系统自动化 ,AUTOMATION OF ELECTRIC POWER SYSTEMS , 编辑部邮箱 ,2000年03期
  • 【分类号】TM773
  • 【被引频次】13
  • 【下载频次】162