节点文献
紫外吸收法测量SO2浓度的电路设计
The electronic circuit design for measuring SO2 concentration by ultraviolet adsorption spectrometry
【摘要】 利用气体对光吸收的原理,建立了双光路测量SO2的数学模型以及测量系统框图,讨论了关键参数的选择,给出一组(0-9999)ppm(10-6)范围内,实际在线测量标准误差小于±50ppm的数据。
【Abstract】 This paper,based on the adsorption principle of the gas to the light,establised the mathematical model of the double optical paths measurement and the frame of the measurement system,discussed the selection of the key parameters and gave a group of data on the range of 0~9999ppm(10~-6),the standard error of online measurment of which is less than ±50ppm.
【关键词】 双光路;
紫外吸收;
二氧化硫浓度测量;
数学模型;
【Key words】 double optical paths; ultraviolet adsorption; SO2 concentration measurement; mathematial model;
【Key words】 double optical paths; ultraviolet adsorption; SO2 concentration measurement; mathematial model;
- 【文献出处】 电测与仪表 ,ELECTRICAL MEASUREMENT & INSTRUMENTATION , 编辑部邮箱 ,2000年04期
- 【分类号】TN710
- 【被引频次】7