节点文献

人工晶体屈光度回归公式的探讨

Discussion of regressive formula of intraocular lens diopter

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 徐雯; 姚克;

【Author】 Xu Wen,Yao Ke Ophthalmologic center,and affiliated hospital of Zhejiang medical univestity,HangZhou 310009

【机构】 浙江医科大学附属第二医院眼科中心;

【摘要】 针对目前临床上常用的SRKⅡ公式在计算人工晶体屈光度时的局限性,对415只后房型人工晶体眼的角膜屈光力、眼轴长度和正视化人工晶体屈光度进行回归分析后,设计出一种不同于传统的线性回归公式的曲线回归公式——二元三次计算公式。结果:二元三次回归公式为一单调递增曲线,呈连续分布,不分区间。利用二元三次回归公式计算的总体标准差小于SRKⅡ公式的总体标准差。结论:二元三次曲线回归公式计算法有助于临床更准确地进行人工晶体屈光度的计算

【Abstract】 Objective:Since some limitaions of SRK Ⅱ formula,the dual cubic curved regressive formula was designed.methods:By means of computer,statistical analysis and regressive treatment of kerato diopter,axial length and emmetropic IOL diopter of 415 pseudophakia was done.Result:The dual cubic regressive formula was a progressively increased curve with continous distribution,and the standard deviation produced by the dual cubic formula was less than the standard deviation produced by SRK Ⅱ formula.conclusion:The dual cubic regressive method could be used to calculate IOL diopter more accurately.

  • 【文献出处】 中国实用眼科杂志 ,CHINESE JOURNAL OF PRACTICAL OPHT , 编辑部邮箱 ,1999年01期
  • 【分类号】R778.1
  • 【被引频次】3
  • 【下载频次】104
节点文献中: 

本文链接的文献网络图示:

本文的引文网络