节点文献
经皮元件用羟基磷灰石材料的组织相容性
HISTOCOMPATIBILITY OF HYDROXYAPATITE FOR PERCUTANEOUS DEVICE
【摘要】 用羟基磷灰石(Ca10(PO4)6(OH)2 , 简称HA) 和对照材料钛合金制备了经皮元件试样, 并将试样穿皮植入受试动物背部皮内进行实验。通过分期对植入局部皮肤组织形态学观察, 就材料对皮肤组织的炎性反应和表皮向下生长情况进行了对照研究。结果表明: 钛合金材料周围组织局部慢性炎性细胞浸润, 轻度充血和水肿, 有严重的表皮向下生长; HA 材料周围组织未见明显炎性细胞浸润, 各观察期均无显著的表皮向下生长, 材料与皮肤组织结合紧密, 组织相容性良好
【Abstract】 The samples of percutaneous device were made of hydroxyapatite (HA) and comparison material, and were percutaneously implanted in the back skin of the animals for experiments. Through histomorphology observations by stages on part skin tissue, the inflammation and the downgrowth of epidermis caused by the materials were comparatively studied. The results demonstrated that part tissue surrounding Ti alloy have chronic inflammatory cells infiltration, slight hyperemia and oedema. Downgrowth of the epidermis is serious, in the case of HA neither clear inflammatory cells infiltration nor marked downgrowth of the epidermis was observed in every observation stage. The material bind tightly with skin tissue. The histocompatibility of HA for percutaneous device is fine.
- 【文献出处】 中国有色金属学报 ,THE CHINESE JOURNAL OF NONFERROUS METALS , 编辑部邮箱 ,1999年S1期
- 【分类号】R318.08
- 【被引频次】6
- 【下载频次】53