节点文献
冰蓄冷空调提高高峰用电转移率的设备选择计算
The Calculation of the Equipment Capacity of the Ice storage Air Conditioning for Increasing the Ratio of Shifting On peak Power
【摘要】 本文介绍了冰蓄冷空调为提高高峰用电转移率在电网高峰期采用制冷机份额供冷运行策略的设备选择计算方法。
【Abstract】 This paper introduces a method for calculating the equipment capacity of the air conditioning with ice storage,where the operating strategy is being adopted,that is ,the chiller has operated at fractional load during the on peak electrical periods in order to increase the ratio of shifting on peak power.
- 【文献出处】 制冷学报 ,REFRIGERATION JOURNAL , 编辑部邮箱 ,1999年04期
- 【分类号】TB657.2
- 【被引频次】6
- 【下载频次】61