The experimental results of degradations of phenolic solution by ultrasound under different cavitation's states are given. The corresponding spectra of sound pressure level and the composite intensities of the sound are compared. The influnces of phenolic solution's concentrations, ferrous salt, and the radiation time of ultrasound on the degradation rates of phenol are shown. The spectral characteristics of different cavitation's states are discussed.