节点文献

甘油三酯酶传感器的研制及应用

Preparation of Triglyceride Enzyme Sensor and Its Application.

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王永生李贵荣吕昌银万载阳刘传湘

【Author】 WANG Yong Sheng, LI Gui Rong, L Chang Yin, WAN Zai Yang, LIU Chuan Xiang(Hengyang Medical College, Hengyang 421001, China).

【机构】 衡阳医学院化学教研室

【摘要】 将脂肪酶固定在pH玻璃电极上,制成甘油三酯酶传感器.对传感器的制作方法和响应性能进行了研究.在37℃,选择TrisHCl缓冲溶液(pH85)为测量介质,所制传感器对甘油三酯的响应线性范围为309×10-6~191×10-3mol/L,响应斜率为327mV/pC,响应时间为5~10min,使用寿命可达25d.用研制的传感器测定了人和兔血清中的甘油三酯含量,结果满意.

【Abstract】 A triglyceride enzyme sensor has been prepared by immobilizing lipase on pH glass electrode. The immobilized methods of lipase and the response characteristics of the sensor were studied.The linear range of detection is 3 09×10 -6 ~ 1 91×10 -3 mol/L for triglyceride with a slope of 32 7 mV/pC in the pH 8 5 Tris HCl buffer solution at 37℃. The response time is 5~10 min. The sensor is relatively stable for 25 days.The sensor has been applied to the determination of triglyceride in serum with satisfactory results.

【关键词】 甘油三酯生物传感器脂肪酶血清
【Key words】 triglyceridesbiosensorlipaseserum
【基金】 湖南省自然科学基金
  • 【文献出处】 生物化学与生物物理进展 ,PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS , 编辑部邮箱 ,1999年02期
  • 【分类号】O657.1
  • 【被引频次】26
  • 【下载频次】192