节点文献

X光多层膜反射镜的损伤与破坏实验研究

EXPERIMENTAL STUDY OF DAMAGE AND DESTROY OF X-RAY MULTI-LAYER REFLECTOR

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 淳于书泰谷渝秋尤永禄黄文忠何颖玲马月英裴舒曹建林

【Author】 CHUNYU Shu-tai, GU Yu-qiu, YOU Yong-lu,HUANG Wen-zhong,HE Ying-ling Southwest Institute of Nuclear Physics and Chemistry,Laser fusion laboratory, Chendu 610003MA Yueying,PEI Shu, CAO Jian-lin Changchun Institute of Optics and Fine Mechanics, Changchun 1

【机构】 西南核物理与化学研究所高温高密度等离子体物理实验室!成都525信箱610003西南核物理与化学研究所高温高密度等离子体物理?

【摘要】 产生 X 光激光的等离子体环境对 X 光多层膜反射镜造成损伤与破坏。通过模拟实验,给出国产 Mo/ Si多层膜反射镜的破坏阈值大约是 010 J/cm 2,在这个辐照剂量下,多层膜表面均方粗糙度明显增加,反射率几乎降至为零。提出了防止多层膜反射镜破坏的一些想法。

【Abstract】 The plasma environment which creates X-ray laser brings the difficulty to the application of X-ray multi-layer reflector. The most difficult is that the X-ray emitted by the plasma destroys and damages the multi-layer reflector. It is shown by the simulated test that the damaged threshold of Mo/Si multilayer reflector made in china is less than 0.10J/cm 2. With he exposure the radiation dose the rood-mean square roughness of multi-layer apparently increases and the reflectivity almost drops to zero. According to these results, the article state some ideas for preventing damages of the multi-layer reflector.

【基金】 国家自然科学基金,中物院科学基金资助课题
  • 【文献出处】 强激光与粒子束 ,HIGH POWER LASER & PARTICLE BEAMS , 编辑部邮箱 ,1999年04期
  • 【分类号】O434.19
  • 【被引频次】1
  • 【下载频次】34
节点文献中: 

本文链接的文献网络图示:

本文的引文网络