节点文献

底部两层框架-抗震墙砖房侧移刚度分析和第三层与第二层侧移刚度比的合理取值

Lateral Stiffness Analysis and Rational Option of Lateral Stiffness Ratio of the Third to Second Story in Masonry Building with Two Stories Frame and Shear Wall at the Bottom

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 高小旺肖伟王菁孟钢王金妹

【Author】 Gao Xiaowang,Xiao Wei,Wang Jing et al.

【机构】 中国建筑科学研究院工程抗震研究所!北京100013

【摘要】 探讨了底部两层框架抗震墙砖房中底部两层层间侧移刚度的简化计算方法,分析指出了计算第二层侧移刚度采用的层间位移应扣除钢筋砼墙在第一层楼板处转角产生的侧移。给出了底部两层框架抗震墙砖房第三层与第二层侧移刚度比的合理取值为1.2~2.0,并且不应小于1.0,供设计人员参考。

【Abstract】 A analysis method of the lateral stiffness for the first and second storey of masonry building with two sto- ries frame and shear walls at the bottom are discussed. The inter-story displacement of the second story lateral stiffness should be deducted from the displacement of the first floor slab rotation in the shear walls. Rational option of lateral stiffness ratio of the third storey to the second- storey in this kind of building is 1.2 ~ 2. 0 and not less than 1. 0.

  • 【文献出处】 建筑结构 ,Building Structure , 编辑部邮箱 ,1999年11期
  • 【分类号】TU352.1
  • 【被引频次】28
  • 【下载频次】111
节点文献中: 

本文链接的文献网络图示:

本文的引文网络