【作者】 夏世斌; 吴华雄; 晏仁生;

【Author】 XIA Shi bin 1,WU Hua xiong 1,YAN Ren sheng 2 (1.Electric Power Testing & Research Institute of Hubei Province,Wuhan 430077,China;2.Safety & Environmental Protection Research Institute,Minstry of Metallurgical Industry,Wuhan 430065,China)

【机构】 湖北省电力试验研究所!湖北武汉430077; 冶金部安全环保研究院!湖北武汉430065;

【摘要】 对荆门热电厂2 号炉电除尘器存在的问题进行了全面分析,探讨了其除尘效率低下的主要原因,并就通过提高比集尘面积,调整气流分布等技术措施来提高其除尘效率,进行了技术研究。结果表明:对电除尘器进口烟气气流分布进行调整可以有效地提高电除尘器的效率。

【Abstract】 The reasons causing low efficiency and bad performance of ESP of NO.2 boiler in Jingmen Power Plant has been comprehensively analysed.The influence of increasing Specific Collecting Surface and adjusting gas distribution of ESP to cillecting efficincy was studied.The results show that adjustments to the inlet gas flow distribution of ESP will bring about considerable improvements in collecting efficiency.

【关键词】 电除尘器; 除尘效率; 气流分布;
【Key words】 ESP; collecting efficiency; gas distribution;