【作者】 赵玉珍薛进敏

【Author】 ZHAO Yu Zhen XUE Jin Min (Institute of Physics,The Chinese Academy of Sciences,No. 8 Nansan Jie,Zhongguancun,Beijing 100080,P.R.China)

【机构】 中国科学院物理研究所

【摘要】 本文研究了用ICP-AES法同时测定纯铁中8种杂质元素:Cr、Cu、Mg、Mn、Mo、Ni、Ti、V的分析方法。研究了铁基体元素对被测元素光谱线的光谱干扰与物理干扰,采用背景扣除法与基体匹配法进行校正。被测元素的检出限为0.4-3.0μg/L,合成试样的回收率为91%-110%,杂质元素含量为0.0003%-0.05%时,测量的相对标准偏差<9%。方法简便、准确、结果满意。

【Abstract】 A method has been studied for simultaneous determination of eight impurity elements Cr,Cu,Mg,Mn,Mo,Ni,Ti and V in pure iron by ICP AES.The spectral interference and physical interference from Fe to the spectral lines of the elements determined are investigated and corrected by the matrix maching and background correction methods. The detection limits determined elements are 0.4-3.0μg/L ,the recoveries are 91%-110%,the relative standard deviations are less than 9% for impurity elements content 0.0003%-0.05%.The method is simple and accurate, and has been used to the analysis of pure iron with satisfactory results.

【关键词】 ICP-AES纯铁
【Key words】 ICP AESPure IronCrCuMgMnMoNiTiV.
  • 【文献出处】 光谱实验室 ,CHINESE JOURNAL OF SPECTROSCOPY LABORATORY , 编辑部邮箱 ,1999年01期
  • 【分类号】O657.31
  • 【被引频次】18
  • 【下载频次】111