节点文献

荧光法同时测定对硝基酚和对氨基酚

Simultaneous Determination of p -Nitrophenol and p -Aminophenol by Fluorimetry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘春英成晓玲钟汉娟方岩雄

【Author】 Liu Chunying 1,Cheng Xiaoling 1,Zhong Hanjuan 1,Fang Yanxiong 2 ( 1.Experiment and Research Centre;2.Dept.of Chemical Engineering,GDUT,Guangzhou 510090,China)

【机构】 广东工业大学

【摘要】 在pH10~30的HCl介质中,荧光物质对氨基酚的激发波长和发射波长分别为271nm和371nm.当有对硝基酚共存时,用硼氢化钠将其还原为对氨基酚,可用荧光光度法同时测定两者的含量.对硝基酚和对氨基酚的检测限分别为027μg/mL和032μg/mL.样品加标回收率分别为对氨基酚:951%~1015%,对硝基酚:898%~1005%.

【Abstract】 In a medium of HCl (pH1 0~3 0),the excitation and emission wavelengths of fluorescence spectrophotometer for p -Aminophenol are 271 nm and 371nm,respectively.When p -Nitrophenol exists in it, p -Nitrophenol can be reduced into p -Aminophenol by adding NaBH4,the amount of two components can be determined simultaneously by fluorimetry.The detection limit of the method is 0 27μg/mL for p -Nitrophenol and 0 32μg/mL for p -Aminophenol.The recovery of standard addition is from 95 1% to 101 5% for p -Aminophenol and from 89 8% to 100 5% for p -Nitrophenol.

【关键词】 对硝基酚对氨基酚还原荧光法
【Key words】 p -Nitrophenolp -Aminophenolreductionfluorimetry
  • 【文献出处】 广东工业大学学报 ,JOURNAL OF GUANGDONG UNIVERSITY OF TECHNOLOGY , 编辑部邮箱 ,1999年02期
  • 【分类号】TQ246
  • 【被引频次】6
  • 【下载频次】173
节点文献中: 

本文链接的文献网络图示:

本文的引文网络