节点文献

双向进气型脉冲管制冷机的分析、实验与改进

ANALYSIS AND IMPROVEMENT OF DOUBLE INLET VERSION PULSE TUBE REFRIGERATOR

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杨鲁伟周远梁惊涛

【Author】 YANG Luwei; ZHOU Yuan; LIANG Jingtao(Cryogenic Laboratory, Chinese Acadeny of Sciences, Beijing 100080)

【机构】 中国科学院低温技术试验中心!北京100080

【Abstract】 Double inlet version pulse tube is analyzed and potential direct current flow is revealed;improvement method of multi--double--inlet version is proposed. An experiment system wasset up. Through eXPeriment, multi--double--inlet version was proved effective to lower therefrigeration temperature: test shows 37K lowest temperature for two double inlet valve and59K lowest temperature for one double inlet valve. This pulse tube has 9.5W/77K coolingcapacity using 55mL valveless. The concept of multi--double--inlet was proposed here for thefirst time.

【基金】 博士后基金;国家超导中心资助
  • 【文献出处】 工程热物理学报 ,JOURNAL OF ENGINEERING THERMOPHYSICS , 编辑部邮箱 ,1999年02期
  • 【分类号】TB651
  • 【下载频次】65
节点文献中: 

本文链接的文献网络图示:

本文的引文网络