节点文献
高碘酸钾-罗丹明6G催化荧光法测定超痕量钌
Catalytic Fluorimetric Determination of Trace Ruthenium with Potassium Periodate and Rhodamine 6G
【摘要】 研究了在盐酸介质中,钌催化高碘酸钾氧化罗丹明6G的反应及动力学条件,建立了高灵敏测定超痕量钌的新方法。线性范围为0.2~1.0ng/25m L,检出限为6.5×10- 12g/m L。方法已用于合成样中钌的测定。
【Abstract】 A new catalytic fluorimetric method for the determination of trace ruthenium is described.The method is based on the catalytic oxidation of rhodamine 6G with potassium periodate in hydrochloric acid medium.The reaction condition was studied,reaction order and apparent energy were determined.The method has high sensitivity and selectivity for determining trace ruthenium.The linear range of the determination is 0 2~1 0ng/25mL and the detection limit for ruthenium is 6 5×10 -12 g/mL.The method has been used to determine ruthenium in synthetics with satisfactory results.
- 【文献出处】 分析试验室 ,ANALYTICAL LABORATORY , 编辑部邮箱 ,1999年06期
- 【分类号】O657.32
- 【被引频次】4
- 【下载频次】71