节点文献

Ti/IrO2涂层阳极热氧化处理温度的选择

Selection of Oxidative Thermal Treatment Temperature of Ti/IrO 2 Coating Anodes

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 潘会波刘宏焦文强

【Author】 Pan Huibo, Liu Hong, Jao Wenqiang (Northwest Institute for Nonferrous Metal Research, Xi’an 710016)

【机构】 西北有色金属研究院

【摘要】 结合铝的表面处理和铜的生箔对阳极的要求,针对Ti/IrO2阳极,用热差分析、电极极化、X光衍射及强化寿命试验,研究了热氧化处理温度对阳极的热分析曲线、电极电位、相结构和强化寿命的影响。在30%H2SO4(质量比),4A/cm2,40℃±5℃下的强化寿命实验表明:小于500℃时,阳极的寿命受涂层的溶蚀控制。大于600℃,阳极的破坏形式以涂层脱落为主,而涂层在500℃~600℃之间处理的阳极的强化寿命最长,Ti/IrO2涂层阳极的热氧化处理温度以500℃~600℃为最佳。

【Abstract】 In order to meet a demand of aluminum surface treatment and copper foil deposition for anodes, the effect of oxidative thermal treatment temperature on thermoanalytical curve, electrode potential, phase structure and strengthening lifetime of Ti/IrO 2 have been studied using thermogravimetry analysis, electropolarized, x ray diffraction and strengthening lifetime experiments. The strengthening lifetime was tested in a solution of 30% H 2SO 4 (weight ratio) at 4A/cm 2 and 40℃±5℃. The results show that the lifetime of an anode made at less than 500℃ is controlled by corrosion of the coating. Peeling of the coating is a major cause of damage for anodes made at temperatures higher than 600℃. The coating made at 500℃~600℃ has the longest lifetime. Optimal oxidative thermal treatment temperature is in the range 500℃ to 600℃ for Ti/IrO 2 coating anode.

  • 【文献出处】 稀有金属材料与工程 ,RARE METAL MATERIALS AND ENGINEERING , 编辑部邮箱 ,1999年01期