节点文献
生物滴滤法处理丙烯酸甲酯废气
The removal of methyl acrylate waste gas by biotrickling filter
【Author】 Hao Wu;Zhenhao Yin;Chengri Yin;Key Laboratory of Natural Resources of Changbai Mountain and Functional Molecules,Ministry of Education,Yanbian University;Analytical and Testing Center,Yanbian University;
【机构】 延边大学长白山生物资源教育部重点实验室; 延边大学分析测试中心;
【摘要】 丙烯酸甲酯是一种重要的化工原料和溶剂广泛应用于各行各业[1]。同时,作为一种挥发性有机化合物,严重影响生态环境和人类健康[2]。本研究构造了一个三段式生物滴滤池并接种了活性污泥,用来处理丙烯酸甲酯废气。实验结果表明,在一定条件下,丙烯酸甲酯的去除率可达100%。固定浓度实验表明,生物滴滤池整体去除能力为8.39 g/m3·h,生物滴滤池的第一层对丙烯酸甲酯废气最大能力最大为5.98 g/m3·h。
【Abstract】 Methyl acrylate is a widely used raw chemical material and it is toxic in humans.In order to treat methyl acrylate waste gas,a three-layer BTF packed with ceramic particles and immobilized with activated sludge was set up.The results shows that in the condition of low inlet concentration,the removal efficiency can be 100%.The result of fixed inlet concentration environment indicates the total elimination capacity of the BTF was 8.39 g/m3·h,the 1st layer of the BTF performed the best EC of 5.98 g/m3·h in the treatment of methyl acrylate.
- 【会议录名称】 中国化学会第30届学术年会摘要集-第二十六分会:环境化学
- 【会议名称】中国化学会第30届学术年会-第二十六分会:环境化学
- 【会议时间】2016-07-01
- 【会议地点】中国辽宁大连
- 【分类号】X701
- 【主办单位】中国化学会