非清洁水凝固潜热采集装置及其热泵技术

NON-CLEAN WATER SOURCE HEAT PUMP TECHNOLOGY WITH FREEZING LATENT HEAT COLLECTION

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李丽娜钱剑峰徐莹郑大宇

【Author】 Li Lina;Qian Jianfeng;Xu Ying;Zheng Dayu;School of Energy & Civil Engineering,Harbin University of Commerce;

【机构】 哈尔滨商业大学能源与建筑工程学院

【摘要】 采集非清洁水凝固热的关键设备是凝固热换热装置。本文综述了城市污水源热泵和地表水源热泵两类非清洁水源热泵的国内外应用与研究现状,指出非清洁水源中蕴含的巨大凝固潜热能够减少矿物能源的匮乏及其环境问题,进而开发了相应的采集凝固热换热装置,并针对装置与系统的运行特性的研究进行了展望。

【Abstract】 The key points device of collection freezing latent heat is heat exchanger device.On the review of non-clean water source heat pump that it includes the city sewage source heat pump and surface water source heat pump application and research situation at home and board,point out that non-clean water contain the tremendous freezing latent heat,collect the freezing latent heat is an effective way to relieve building energy and environmental issues,and then developed the corresponding heat exchanger device of collection freezing latent heat,look forward to the study of the device and the operating characteristics of system.

  • 【会议录名称】 2013中国制冷学会学术年会论文集
  • 【会议名称】勇于创新,服务发展——2013中国制冷学会学术年会
  • 【会议时间】2013-11-05
  • 【会议地点】中国湖北武汉
  • 【分类号】TU83
  • 【主办单位】中国制冷学会