节点文献

锅炉烟道系统强振问题的分析和治理

Vibration Analysis and Treatment of the Flue Duct of a Gas-Fired Boiler

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 谢民

【Author】 Xie Min;Hunan Valon Xiangtan Iron and Steel Group Co.,Ltd.;

【机构】 湖南华菱湘潭钢铁集团有限公司

【摘要】 针对湘潭钢铁有限公司动力厂130 t/h燃气锅炉烟道系统振动严重超标的问题,通过对引风机及烟道系统的振动测试和分析,得出其振动的主要原因是因烟道内气流不均匀而出现了局部涡流、风机内出现旋转脱流以及形成二次流所致.经采取在风机内加装整流器、烟道内加装导向叶片及烟道系统加固等技术措施治理后,其振动大大降低,达到了预期目的.

【Abstract】 The vibration of the induced draft for the flue duct system of a gas-fired 130 t/h boiler was tested and analyzed. The results show that the vibration of the flue duct is caused by the local eddy which is resulted from the non-uniform flow and the fan is caused by the secondary flow which is resulted from the whirling flow-away. By installing a air flow rectifier in the fan, a damper in the duct and a reinforced structure for the whole flue duct system, the vibration was greatly decreased, which is a satisfactory result for the boiler owner.

【关键词】 锅炉烟道系统振动分析治理
【Key words】 boilerflue duct systemvibration analysis treatment
  • 【会议录名称】 第八届(2011)中国钢铁年会论文集
  • 【会议名称】第八届(2011)中国钢铁年会
  • 【会议时间】2011-10-26
  • 【会议地点】中国北京
  • 【分类号】TK229.8
  • 【主办单位】中国金属学会
节点文献中: 

本文链接的文献网络图示:

本文的引文网络