节点文献
某电厂220MW机组接长轴振动故障诊断及处理
Vibration Diagnosis and Disposal of Extended Shaft for 220MW Unit of One Power Plant
【Author】 LIU Shu-peng;ZHANG Wei-jun;ZHANG Hong;Xi’an Thermal Power Research Institute Co.,Ltd;Guodian Jingyuan Power Generation Co.,Ltd;
【机构】 西安热工研究院有限公司汽轮机及热力系统技术部; 国电靖远发电有限公司;
【摘要】 某电厂220MW机组3号轴承相对轴振动和座振动均超标。通过分析历史数据,诊断振动原因为:中-低压转子中间接长轴设计结构薄弱,机组甩负荷停机使得接长轴产生了较大地二阶质量不平衡。通过采用现场高速动平衡技术,在接长轴上加重,降低相关测点振动值,使机组振动达到优良水平。
【Abstract】 The 3th relative shaft vibration and bearing vibration have been exceeded standard.By analyzing the historical data,diagnosed the vibrational reasons are that the design structure of the extended shaft is weak and then load shedding made the extended shaft produced greatly second-order mass imbalance.Through adopting field dynamic balancing method,the trial weights were added onto the extended shaft to reduce the 3th relative shaft vibration and bearing vibration.The unit vibrations eventually were controlled to a satisfied level.
【Key words】 220MW turbo-generator unit; extended shaft; vibration; dynamic balancing;
- 【会议录名称】 中国电机工程学会第十三届青年学术会议论文摘要集
- 【会议名称】中国电机工程学会第十三届青年学术会议
- 【会议时间】2014-10-16
- 【会议地点】中国重庆
- 【分类号】TM311;TH165.3
- 【主办单位】中国电机工程学会、重庆市科学技术协会