节点文献

基于OMAP的变电站智能防误终端的设计与开发

Design and implementation of intelligential mistake precaution terminal for transformer substation based on OMAP

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 马洪连孟新雨丁男

【Author】 MA Hong-lian,MENG Xin-yu,DING Nan(Department of Computer,Dalian University of Technology,Dalian 116023,China)

【机构】 大连理工大学计算机系

【摘要】 介绍了基于OMAP的变电站智能防误终端,该终端能严格遵照“五防”要求进行防误操作,并且进行语音记录,将变电站的刀闸信息与所有操作信息通过GPRS网络实时传送到电力系统调度中心与变电所主控室的PC机上,从而确保电力系统安全运行。大量实地实验结果表明该终端具备实时性和对大数据量的处理能力,弥补了过去防误系统存在的弊病。GPRS网络技术的引进提高整个系统的实时性,也适应当今网络化社会的要求。

【Abstract】 The intelligential mistake precaution terminal with voice memory particular was introduced.The terminal according to “five rules” can be prevented from wrong operations.To make sure the security of the electric system,it sends the information of switched and operations to the computer in the control center with GPRS network.It is proved that the terminal is a real time system and has the ability of processing quantity of data.It solves the problems of previous mistake precaution system,and becomes a real time system with introducing GPRS network technology into the terminal,which meets the need of network society nowadays.

【关键词】 Omap5912网络技术防误终端
【Key words】 OMAP5912network technologymistake precaution terminal
  • 【会议录名称】 2007年中国智能自动化会议论文集
  • 【会议名称】2007年中国智能自动化会议
  • 【会议时间】2007-08
  • 【会议地点】中国甘肃兰州
  • 【分类号】TP273.5
  • 【主办单位】中国自动化学会智能自动化专业委员会
节点文献中: 

本文链接的文献网络图示:

本文的引文网络