节点文献

热管技术应用于冷却塔节水的理论分析

ANALYSIS OF SAVING WATER IN THE COOLING TOWER USING HEAT PIPE

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李芳王景刚刘金荣

【Author】 Li Fang Wang Jinggang Liu Jinrong( Hebei University of Engineering, Handan 056038) ( Zhong Nan Construction Group Company Limited, HangZhou 310052 )

【机构】 河北工程学院城建学院浙江中南建设集团有限公司

【摘要】 本文对冷却塔的蒸发水量损失的因素进行了分析、介绍了冷却塔内饱和湿空气的形成和凝结过程,利用热管技术降低冷却塔除水器上方的饱和湿空气的温度实现降温、减湿过程,回收饱和湿空气中的水蒸气,通过饱和湿空气的相对湿度和热管换热的计算,得出不同温降下的集水效率和所须的热管面积,并对回收冷却塔饱和湿空气中的水蒸气的措施进行了简述。

【Abstract】 The factors of evaporating water losses were analyzed and calculated in the cooling tower based on the results of operating test. The temperature of the saturated air is fallen utilize heat pipe for collecting the steam water losses. The rate of the collecting water and the area of heat pipe are shown in different temperature decline according to the relative humidity calculation of moist air and caloric exchange of heat pipe. Some measures of water saving are introduced.

【基金】 河北省自然科学基金项目(502388);河北省科学技术研究与发展计划项目(04547007D-2)
  • 【会议录名称】 制冷空调新技术进展——第三届制冷空调新技术研讨会论文集
  • 【会议名称】第三届制冷空调新技术研讨会
  • 【会议时间】2005-04
  • 【会议地点】中国杭州
  • 【分类号】TB657
  • 【主办单位】中国制冷学会
节点文献中: 

本文链接的文献网络图示:

本文的引文网络