节点文献
BESⅢ漂移室模型束流测试的初步结果
Preliminary beam test results of a prototype of BESⅢ DC
【作者】 刘建北; 秦中华; 伍灵慧; 陈昌; 庄保安; 陈元柏; 金艳; 刘荣光; 马骁妍; 马媛媛; 唐晓; 王岚; 徐美杭; 张桂芳; 朱旻萱; 朱启明;
【Author】 LIU Jian-bei,QIN Zhong-hua,WU Ling-hui,CHEN Chang,ZHUANG Bao-an,CHEN Yuan-bo,JIN Yan,LIU Rong-guang,MA Xiao-yan,MA Yuan-yuan,TANG Xiao,WANG Lan,XU Mei-hang,ZHANG Gui-xiang,ZHU Min-xuan,ZHU Qi-ming(Institute of High Energy Physics,The Chinese Academy of Sciences,Beijing, 100039,China)
【机构】 中国科学院高能物理研究所;
【摘要】 利用日本KEK 12GeV/c质子同步加速器的π-2实验束对BESⅢ漂移室的一个多层多单元模型的性能进行了测试,包括高压扫描,极角扫描,动量扫描等多项扫描测试,以及模型在1T磁场中的性能测试。对测试数据的初步分析表明:BESⅢ漂移室最佳工作电压约为2150-2200V,空间分辨可达150-200μm,在36次取样下dE/dx分辨好于5%。
【Abstract】 A beam test of a prototype chamber for BESⅢ DC was carried out at the π-2 beam line of KEK 12GeV/c proton synchrotron in Japan. The prototype chamber was tested for various operating conditions such as high voltage, beam momentum,incident angle, etc. In addition the porformance in 1T magnetic field was studied. The preliminary results show that the optimum high voltage for BESⅢ DC isabout 2150 - 2200V and a spacial resolution of 150 - 200μm and a dE/dx resolution better than 5% with 36 samples can be obtained.
- 【会议录名称】 第十二届全国核电子学与核探测技术学术年会论文集
- 【会议名称】第十二届全国核电子学与核探测技术学术年会
- 【会议时间】2004-11
- 【会议地点】中国云南昆明
- 【分类号】TL817
- 【主办单位】中国电子学会核电子学与核探测技术分会、中国核学会核电子学与核探测技术分会