节点文献
一种考虑对不换位单回线的双端故障测距算法
An algorithm basing on double ends and considering untranspositional lines
【Author】 Liang Huawei~1 Liu Wanshun~2 Sheng Zhihui~1(1.GUODIAN NANJING AUTOMATION COMPANY Ltd.;2.NORTH CHINA ELECTRICAL POWER UNIVERSITY (BEIJING))
【摘要】 在输电线路故障测距的研究中,并不是所有的输电线路均为换位线路,所以对不换位线路的故障测距研究存在一定的实际意义。本文提出一种基于分布参数模型和等效参数估计的双端测距算法。该算法只利用一种简单的线性变换和故障前的电压电流,在线估计出不换位线路对应的等效换位参数。EMTP仿真结果表明,该算法能够较准确的测量出不换位线路故障距离,具有一定的工程实际应用意义。
【Abstract】 In the researches of fault location,because all the lines are not transpositional lines,it is necessary of considering the fault location of untranspositional lines.This paper proposed that a double ends algorithm basing on the distributed parameters model and the equivalent parameter estimation.The algorithm utilizes only an easy linear transformation and the voltages and currents preceding the fault,can estimate the variation of the line parameters on-line.The result of EMTP shows that the algorithm can accurately measure the fault location of untranspositional lines.
【Key words】 Fault Location; Untranspositional Lines; Algorithms of double ends;
- 【会议录名称】 2006中国电力系统保护与控制学术研讨会论文集
- 【会议名称】2006中国电力系统保护与控制学术研讨会
- 【会议时间】2006-09
- 【会议地点】中国广东珠海
- 【分类号】TM755
- 【主办单位】中国电器工业协会继电保护及自动化设备分会、清华大学电机工程与应用电子技术系、华中科技大学电气与电子工程学院