节点文献

金刚石薄膜探测器时间响应性能研究

Time response of CVD diamond film detectors

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王兰欧阳晓平范如玉

【Author】 WANG Lan OUYANG Xiao-ping FAN Ru-yu(1.Department of Engineering Physics,Tsinghua University,Beijing,100084;2.Northwest Institute of Nuclear Technology,Xi’an,710024)

【机构】 清华大学工程物理系西北核技术研究所

【摘要】 研制出可以用于脉冲辐射探测的 CVD 金刚石薄膜探测器,通过理论计算和实验研究,讨论了金刚石探测器时间响应的影响因素。探测器的面积、厚度是影响其时间响应的主要因素,金刚石材料中的杂质和缺陷会使其时间响应变慢。选用高质量的金刚石薄膜可以制成适用于纳秒级脉冲辐射探测的半导体探测器。

【Abstract】 The speed of a CVD diamond detector is faster than a Si-PIN detector with the same size. Two CVD diamond film detectors of different size and quality are made and factors which may affect the time response of a CVD diamond film detector are discussed through theoretic and experimental researches.The area and thickness of the film are the main factors. And the impurities and traps in the film slow the detectors.CVD diamond detectors for ns pulsed radiation detection can be made by using high quality diamond films with the proper size.

  • 【会议录名称】 全国第六届核仪器及其应用学术会议论文集
  • 【会议名称】全国第六届核仪器及其应用学术会议
  • 【会议时间】2007-11
  • 【会议地点】中国广西桂林
  • 【分类号】TL816
  • 【主办单位】中国核学会核电子学与核探测技术分会、中国电子学会核电子学与核探测技术分会
节点文献中: 