直流融冰兼SVC装置晶闸管阀组通态损耗研究
Thyristor Valve-state Losse of the DC Deicer-SVC Device
【Author】 LI Haisheng[1,2],LI Baode[1]TAN Jiancheng[1] 1.College of Electrical Engineering,Guangxi University,Nanning 530004,China;2.Liuzhou Bureau,China Southern Power Grid EHV Power Transmission Company,Liuzhou,545006,China
【机构】 广西大学电气工程学院; 南方电网超高压输电公司柳州局;
【摘要】 目前国内外尚没有计算SVC晶闸管网损的行业标准。IEEE SVC选型指南中提供了晶闸管阀组损耗的参考计算方法,与SVC晶闸管实际测量损耗值相差较大。因此有必要研究SVC晶闸管阀组损耗计算的新算法,更精确地估算晶闸管阀组的损耗。本文对阀组损耗的主要部分晶闸管阀通态损耗进行研究,提出一种基于管压降模型的晶闸管通态损耗的新算法,对5STP25L5200型号晶闸管进行理论线损计算,与厂家实测数据相吻合。
【Abstract】 At present,SVC thyristor loss calculation remains as a challenge in the power industry.IEEE Guide for the Functional Specification of SVCs provides a reference model for thyristor valve loss estimae,may not accurate to the SVC/HVDC De-icer in service at the 500kV Guilin Substation.This paper investigates the SVC thyristor valve loss components,proposes a new algorithm for thyristor valve on state loss calculation,based on the pressure drops.Apply the new algorithm on 5STP25L5200 type thyristor,the calculated theoretical loss matches the factory test results.
【Key words】 SVC Loss,thyristor voltage drop; thyristor on-state loss;