节点文献

137Csγ射线CT多探测线路均一化响应模型

Synchronous Response Model of 137Cs γ-ray CT Multi-detection Circuits

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘跃进李伟白鸽韩路长曹阳

【Author】 Liu Yuejin Li Wei Bai Ge Han Luchang Cao Yang (College of Chemical Engineering,Xiangtan University,Xiangtan 411105,China)

【机构】 湘潭大学化工学院

【摘要】 基于137Csγ射线七NaI(T1)探测器均一化测量响应曲线,提出并建立了均一化探测γ射线负累积分布与密度分布两种响应模型,所建立的偏高斯密度分布模型与多项式模型同时模拟了γ射线脉冲高能段和康普顿效应低能段的响应规律,对模型参数做了敏感性分析。该模型可用于137Csγ射线CT多探测线路的均一化识别与检验。

【Abstract】 Based on seven NaI(Tl) detectors’ synchronous measurement response curves for 137Csγray,two response function models of both negative accumulative distribution and density distribution are proposed and established.The response characteristic of both high energy impulse and compton effect agree well with partial Gaussian function model and polynomial model established in this paper with the seven NaI(Tl) multi-detection circuits.The sensitivity parameters that have much influence on the response density function are discussed.The established density distribution response model can be used to distinguish and examine the synchronous of 137Csγray multi-detection circuits.

【基金】 国家自然科学基金(20776121);湖南省高校环境友好催化与绿色化工工艺科技创新团队支持计划;湖南省高校绿色催化与反应工程重点实验室开发基金资助
  • 【会议录名称】 2010振动与噪声测试峰会论文集
  • 【会议名称】2010振动与噪声测试峰会
  • 【会议时间】2010-04-28
  • 【会议地点】中国北京
  • 【分类号】TH878.1
  • 【主办单位】中国电子学会、中国振动工程学会
节点文献中: 

本文链接的文献网络图示:

本文的引文网络