节点文献

一种提升时差法超声波流量计精度的方法

A Modified Algorithm to Improve the Accuracy of Ultrasonic Flow-meter with Time Difference Method

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 段允王让定孙广清

【Author】 DUAN Yun,WANG Rang-ding,SUN Guang-qing(School of Information Science and Engineering,Ningbo University,Ningbo 315211,China)

【机构】 宁波大学信息科学与工程学院

【摘要】 应用时差法测量原理设计的超声波流量计,计时的准确度直接影响流量计计量精度.采用53H的改进算法能有效剔除由混响、电磁干扰等引起的误差计量,实验仿真和在硬件上的实际应用,证明该算法是有效的.

【Abstract】 The accuracy of the time testing directly influences the measurement precision of the ultrasonic flow-meter with time difference method. The emission signal will scatter due to inhomogeneity of the fluid interface. The scattering signal overlaps and the reverberation forms. It seriously affects the measurement precision. In this paper,the improved algorithm of 53H can effectively remove error measurement,which is caused by the reverberation and electromagnetic interference. The experimental simulations and practical application of hardware show this algorithm is effective.

  • 【会议录名称】 2009年全国开放式分布与并行计算机学术会议论文集(上册)
  • 【会议名称】2009年全国开放式分布与并行计算机学术会议
  • 【会议时间】2009-09-26
  • 【会议地点】中国新疆乌鲁木齐
  • 【分类号】TH814.92
  • 【主办单位】中国计算机学会开放系统专业委员会
节点文献中: 

本文链接的文献网络图示:

本文的引文网络