【作者】 何铁陈渊安力郭海萍郑普王新华

【Author】 HE Tie,CHEN Yuan,AN Li,GUO Hai-ping,ZHENG Pu,WANG Xin-hua (Institute of Nuclear Physics and Chemistry,China Academe of Engineering and Physics,P.O.Box 919-213, Mianyang,621900,China)

【机构】 中国工程物理研究院核物理与化学研究所

【摘要】 为了减小α粒子在靶室内壁的散射作用对时间谱的测量的影响,设计了锥形准直筒对散射的粒子进行屏蔽,抑制了与α散射相关的中子产生的γ射线,提高了时间谱的分辨,同时也降低了部分与α-γ时间不相关的本底。在有、无锥形准直筒的条件下,α-γ符合时间谱的分辨分别为:3.4ns和6.4ns。

【Abstract】 The resolution ofα-γcoincidence time spectrum is an important factor to obtain the excellent prompt gamma spectrum in the associated.particle technique.In this paper,we present the scattering ofαparticle in the D-T reaction chamber wall is the main causation to the resolution of time spectrum.A cone-shaped.particle collimator was designed to restrain the gamma induced by the neutron which is correlated to the scattering.Thus, the resolution of the time spectrum was improved.Measurements show that with and without the collimator,the resolution of the time spectrum are 3.4ns and 6.4ns,respectively.

  • 【会议录名称】 第七届全国核仪器及其应用学术会议暨全国第五届核反应堆用核仪器学术会议论文集
  • 【会议名称】第七届全国核仪器及其应用学术会议暨全国第五届核反应堆用核仪器学术会议
  • 【会议时间】2009-07-20
  • 【会议地点】中国青海西宁
  • 【分类号】TL81
  • 【主办单位】中国核学会核电子学与核探测技术分会、中国电子学会核电子学与核探测技术分会、中核(北京)核仪器厂、《核电子学与探测技术》编辑部