节点文献
ICP-MS应用于白刚玉、铬刚玉中7种杂质元素的检测研究
Analysis of 7 Elements in White Corundum and Chrome Corundum by ICP-MS
【作者】 张苗; 许宏民; 许健; 苗贵东; 项海波; 陶琳; 王乐; 刘胜; 王克刚;
【Author】 ZHANG Miao 1*,XU Hong-min 1,XU Jian 1,MIAO Gui-dong 1,XIANG Hai-bo 2,TAO Lin 1,WANG Le 1,LIU Sheng 1,WANG Ke-gang 1 (1.Zibo Entry-Exit Inspection and Quarantine Bureau,Zibo 255031,China;2.Shandong Entry-Exit Inspection and Quarantine Bureau,Qingdao 266001,China)
【机构】 淄博出入境检验检疫局; 山东出入境检验检疫局;
【摘要】 经过微波消解处理后,采用电感耦合等离子体质谱(ICP-MS)法测定了白刚玉、铬刚玉样品中硅、铁、钾、钠、铬、钙、镁元素的含量,并用加标回收的方法评价了方法的准确度。研究结果表明,已知样品在200、100、50μg加标水平的回收率为92%~101%,RSD在10%以内,方法对上述7种杂质元素的检出限分别为0.48、0.096、0.064、0.46、0.065、0.086、0.075mg/kg。以样品主体元素作基体匹配及在线内标加入,有效地克服了因基体效应带来的测量偏差,最大程度地减少了测定过程中的谱线干扰。
【Abstract】 Corundum was dissolved by microwave digestion,and contents of Si,Fe,K,Na,Cr,Ca,Mg were determined by ICP-MS.The accrurancy and feasibility of the method were evaluated by checking standard samples,spiked recovery and precision.The results showed that the recoveries ranged from 92% to 101% and the precisions (RSD) for 11 replicate measurements of sample solutions were less than 10%.The limits of detection of seven elements were 0.48,0.096,0.064,0.46,0.065,0.086,0.075mg/kg,respectively.The matrix effect and interface effect were corrected by using the on-line addition of internal standards and the standard solution.
- 【会议录名称】 山东出入境检验检疫局专刊
- 【会议时间】2012-12-01
- 【分类号】TQ164.2;O657.63