节点文献
塞型铜箔量热计制作工艺与散差分析
The fabrication processes and consistency analysis of Plug-shaped copper foil calorimeter
【Author】 Zhang Shi-zhong,Chen Hong Jang Yang,Dong Zhi-cheng (State Key Laboratory of High Temperature Gas dynamics,Institute of Mechanics, Chinese Academy of Sciences,Beijing,100190,China)
【机构】 中国科学院力学研究所高温气体动力学国家重点实验室;
【摘要】 塞形铜箔量热计在测量热流值高、冲刷大的场合应用十分广泛,但由于其偏离非理想条件和制作工艺造成的散差分布也比较大。从塞形铜箔量热计的测热原理出发,采用不同制作工艺制作了一批量热计,通过爆轰驱动激波管实验测量驻点热流值,根据实验结果分析不同的制作工艺对塞形铜箔量热计测量结果造成的误差,从而提高塞形铜箔量热计的散差分布。
【Abstract】 Plug-shaped copper foil calorimeter,which is widely used in harsh situations with high heat flux,has a poor consistency because of its deviation from the non-ideal conditions due to different fabrication processes.Base on the principle of the calorimeter, several calorimeters are manufactured by different fabrication processes,and are used to measure the heat-flux values at stagnation point of a serai-sphere model through detonation driven shock tube experiments.The experimental results are analyzed to find out feasible methods for improving the performance of the sensors.
【Key words】 plug-shaped copper foil calorimeter; detonation-driven shock tube; heat-flux measurement;
- 【会议录名称】 第十五届全国激波与激波管学术会议论文集(下册)
- 【会议名称】第十五届全国激波与激波管学术会议
- 【会议时间】2012-07-13
- 【会议地点】中国浙江杭州
- 【分类号】TH81
- 【主办单位】中国力学学会激波与激波管专业委员会、浙江理工大学机械与自动控制学院