节点文献
空气源热泵复合水蓄热供热系统优化配置研究
Research on optimal configuration of hybrid air source heat pump heating system with water-based thermal storage
【摘要】 出于平衡电网负荷和缓解弃风消纳的目的,提出了空气源热泵复合水蓄热供热系统方案。基于TRNSYS软件搭建仿真模型,以空气源热泵功率、电锅炉功率及蓄热水箱容量为决策变量,以费用年值为优化目标,对库尔勒市某热源厂热泵复合供热系统进行优化配置研究。结果表明:平电价对复合供热系统的最佳蓄热比影响显著,而峰电价对其几乎无影响。对于本案例,水蓄热电锅炉供热系统最佳蓄热比为0.67,空气源热泵复合水蓄热供热系统热源配置最佳方案为空气源热泵配置比K=0.4,蓄热比X_k=0.5。综合经济性、节能性和环境效益,空气源热泵复合水蓄热供热系统有显著优势。
【Abstract】 To address grid load balancing and mitigate wind power curtailment, a hybrid heating system combining air source heat pumps with water-based thermal storage is proposed. A simulation model was developed using TRNSYS software. With air source heat pump power, electric boiler power, and thermal storage tank capacity as decision variables, and annual worth as the optimization objective, this model was applied to optimize the configuration of the hybrid heat pump heating system at a thermal energy plant in Korla city. The results demonstrate that flat electricity prices significantly impact the optimal heat storage ratio for the hybrid system. Conversely, peak electricity prices exhibit minimal influence. For the studied case, the optimal heat storage ratio for a water-based storage thermal electric boiler system is 0.67. The optimal configuration for the hybrid air source heat pump heating system is K=0.4(heat pump proportion) and X_k=0.5(thermal storage ratio).Considering cost efficiency, energy conservation, and environmental sustainability, the hybrid air source heat pump heating system with water-based thermal storage offers clear advantages.
【Key words】 air source heat pump; heat storage system; optimization design;
- 【文献出处】 中原工学院学报 ,Journal of Zhongyuan University of Technology , 编辑部邮箱 ,2025年04期
- 【分类号】TU833.1
- 【下载频次】33