节点文献

STE和SE定量及定性参数对BI-RADS 4类乳腺病灶的诊断价值及与HER2表达的相关性

The diagnostic value of quantitative and qualitative parameters of STE and SE in BI?RADS 4 breast lesions and their correlation with HER2 expression

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 柯强; 刘晓芳; 任家仪; 王超; 陈武;

【Author】 KE Qiang;LIU Xiaofang;REN Jiayi;WANG Chao;CHEN Wu;School of Medical Imaging,Shanxi Medical University;Department of Ultrasound Imaging,The First Hospital of Shanxi Medical University;

【通讯作者】 陈武;

【机构】 山西医科大学医学影像学院; 山西医科大学第一医院超声影像科;

【摘要】 目的:比较声触诊弹性成像(sound touch elastography,STE)和应变弹性成像(strain elastography,SE)定性及定量参数对乳腺影像报告和数据系统(Breast Imaging Reporting and Data System,BI-RADS)4类乳腺病灶良恶性的鉴别诊断价值,并探讨其参数与BI-RADS 4类乳腺恶性病灶中人表皮生长因子受体2(human epidermal growth factor receptor 2,HER2)表达的相关性。方法:选取2022年11月—2023年9月于山西医科大学第一医院检查且诊断为BI-RADS 4类乳腺病灶患者的临床病理学资料,获取STE与SE定量、定性参数[STE弹性最大值(Emax)、STE定性评分值、SE应变比(strain ratio,SR)及SE定性评分值],比较两种超声弹性技术参数鉴别BI-RADS 4类乳腺病灶良恶性的价值以及与BI-RADS 4类乳腺恶性病灶HER2表达的相关性。结果:共纳入106例患者,共106个病灶。BI-RADS 4类乳腺良性与恶性病灶的Emax、STE评分、SR和SE评分的差异有统计学意义(P<0.05);与病理学检查结果相比较,Emax、STE评分、SR、SE评分根据截断值诊断BI-RADS 4类乳腺病灶良恶性的差异有统计学意义(P<0.05),Emax、STE评分、SR的诊断效能与“金标准”相比一致性一般(Kappa=0.436,0.420,0.502),SE评分的诊断效能与“金标准”相比一致性较强(Kappa=0.626),SE评分(AUC=0.883)受试者工作特征(receiver operating characteristic,ROC)曲线的曲线下面积(area under curve,AUC)均高于Emax(AUC=0.743)、STE评分(AUC=0.756)、SR(AUC=0.783)诊断,具有最大的诊断效能,差异有统计学意义(P<0.05);在BI-RADS 4类乳腺恶性病灶中,Emax与SE评分在HER2阳性表达与阴性表达之间差异有统计学意义(P<0.05)。Emax、SE评分与HER2阳性表达呈正相关(r=0.458、0.356)。Emax与SE评分诊断HER2阳性表达的最佳截断值为123.75 kPa和4分,灵敏度为81.2%和62.5%,特异度为60.5%和68.4%,AUC为0.766和0.689。结论:STE与SE技术在应用于鉴别BI-RADS 4类乳腺病灶时,SE评分的诊断效能较高;Emax、SE评分与HER2阳性表达均呈正相关,Emax与SE评分鉴别BI-RADS 4类乳腺恶性病灶HER2阳性表达具有重要价值。

【Abstract】 Objective:To compare the diagnostic value of qualitative and quantitative parameters of sound touch elastography(STE) and strain elastography (SE) in differentiating benign and malignant Breast Imaging Reporting and Data System (BI-RADS) 4breast lesions,and to explore the correlation between the parameters and the expression of human epidermal growth factor receptor2 (HER2) in BI-RADS 4 breast malignant lesions.Methods:The clinicopathological data of patients with BI-RADS 4 breast lesions diagnosed by ultrasound examination in The First Hospital of Shanxi Medical University were selected.The quantitative and qualitative parameters of STE and SE were obtained:STE maximum elasticity (Emax),STE qualitative score,SE strain ratio (SR)and SE qualitative score.To compare the value of two ultrasonic elastography parameters in differentiating benign and malignant BI-RADS 4 breast lesions and their correlation with HER2 expression in BI-RADS 4 breast malignant lesions.Results:A total of106 patients with 106 lesions were included.The difference of Emax,STE score,SR and SE score between benign and malignant lesions of BI-RADS 4 breast was statistically significant (P<0.05).Compared with the pathological results,the difference of Emax,STE score,SR and SE score in the diagnosis of benign and malignant BI-RADS 4 breast lesions according to the cut-off value was statistically significant (P<0.05).The diagnostic efficacy of Emax,STE score and SR was generally consistent with that of the gold standard (Kappa=0.436,0.420,0.502),and the diagnostic efficacy of SE score was more consistent with that of the gold standard(Kappa=0.626).The area under the receiver operating characteristic (ROC) curve (AUC) of SE score (AUC=0.883) was higher than that of Emax (AUC=0.743),STE score (AUC=0.756) and SR (AUC=0.783) diagnosis,with the greatest diagnostic efficiency,and the difference was statistically significant (P<0.05).In BI-RADS 4 breast malignant lesions,the difference of Emax and SE scores between HER2 positive expression and negative expression was statistically significant (P<0.05).Emax and SE scores were positively correlated with HER2 positive expression (r=0.458,0.356).The best cut-off value of Emax and SE score in the diagnosis of HER2positive expression was 123.75 kPa and 4 points,the sensitivity was 81.2%and 62.5%,the specificity was 60.5%and 68.4%,and the AUC was 0.766 and 0.689.Conclusion:The diagnostic efficacy of SE score was higher when STE and SE techniques were used to identify BI-RADS 4 breast lesions.Emax and SE scores were positively correlated with HER2 positive expression.Emax and SE score are of great value in identifying HER2 positive expression in BI-RADS 4 breast malignant lesions.

【基金】 山西省基础研究计划自然科学研究面上项目(20210302123259)~~
  • 【分类号】R445.1;R737.9
  • 【下载频次】15
节点文献中: 

本文链接的文献网络图示:

本文的引文网络