节点文献
2种富集方法在城市污水新型冠状病毒检测中的效能差异分析
Analysis on the efficacy differences of two enrichment methods in detection of SARS-CoV-2 in municipal sewage
【摘要】 目的 对比聚乙二醇沉淀法与磁珠法在城市污水新型冠状病毒(SARS-Co V-2)检测中的效能差异,为新型冠状病毒预警监测和科学防控提供理论依据。方法 通过新型冠状病毒标准物质梯度稀释得到标准曲线,计算聚乙二醇沉淀法和磁珠法的回收率,并采用χ2检验、Wilcoxon秩和检验来比较2种方法对污水中新冠病毒的检出率与检出浓度。结果 在加标试验中,聚乙二醇沉淀法和磁珠法对Orf1a/b基因回收率分别为3.08%和18.74%,N基因的回收率分别为3.46%和21.52%。采用聚乙二醇沉淀法、磁珠法对414份污水样本分别进行检测,Orf1a/b基因的检出率分别为37.92%和43.24%,N基因的检出率分别为63.29%和67.39%,差异均无统计学意义(Orf1a/b基因:χ2=1.025,P=0.311;N基因:χ2=0.323,P=0.570);Orf1a/b基因检出浓度M(P25~P75)分别为0.70(0.38~1.41)copies/m L和3.01(1.10~6.31)copies/m L,N基因检出浓度M(P25~P75)分别为4.43(2.18~12.54)copies/m L和18.11(6.77~50.41)copies/m L,差异均有统计学意义(Orf1a/b基因:Z=-12.977,P<0.001;N基因:Z=-14.821,P<0.001)。结论 2种富集方法在城市污水中新冠病毒的检出率无明显差异,但磁珠法的回收率更高,2种富集方法均可为病毒监测提供数据支持。
【Abstract】 Objective To compare the efficacy of the polyethylene glycol precipitation method and the magnetic bead method in the detection of novel coronavirus (SARS-Co V-2) in municipal sewage,and to provide a theoretical basis for the early monitoring and scientific prevention and control of SARS-Co V-2.Methods The standard curve was obtained by gradient dilution of the SARS-CoV-2 standards.The recovery rate of the polyethylene glycol precipitation method and the magnetic bead method were calculated.Both the χ~2 test and the Wilcoxon nonparametric rank-sum test were applied to calculate the detection rate and concentration of the SARA-CoV-2.Results In the spiking experiments,the recoveries of Orf1a/b genes were 3.08% and 18.74% by polyethylene glycol precipitation and magnetic bead method,while those of the N gene were 3.46% and 21.52% ,respectively.A total of 414 sewage samples were detected using polyethylene glycol precipitation and magnetic bead method respectively.The detection rates of Orf1a/b genes were 37.92% and 43.24% ,respectively,and those of N genes were 63.29% and 67.39% ,respectively,which showed no significant differences (Orf1a/b gene: χ~2 =1.025,P=0.311;N gene: χ~2 =0.323,P=0.570).The detected concentrations M (P25~P75) of the Orf1a/b genes were 0.70 (0.38~1.41)copies/m L and 3.01 (1.10~6.31) copies/m L,respectively,while those of the N gene were 4.43 (2.18-12.54) copies/m L and18.11 (6.77~50.41) copies/m L,respectively.The differences were all statistically significant (for the Orf1a/b gene:Z=-12.977,P<0.001;for the N gene:Z=-14.821,P<0.001).Conclusions There was no significant difference in the detection rate of SARA-CoV-2 in municipal sewage between the two enrichment methods,but the recovery rate of the magnetic bead method was higher.Both the enrichment methods can provide data support for virus monitoring.
- 【文献出处】 中国校医 ,Chinese Journal of School Doctor , 编辑部邮箱 ,2025年05期
- 【分类号】X832
- 【下载频次】18