眼部超声可视化生物规范测量指南(2024)

Standard operating guidelines for ocular ultrasound examination and measurement (2024)

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 邵毅; 杨文利; 王岩; 黄永志; 苏兆安; 林松; 谭钢; 杨青华; 陶勇; 迟玮; 沈吟; 黄锦海; 马健; 杨卫华; 张慧; 魏雁涛; 李世迎; 计丹; 蔡建奇; 胡亮; 刘光辉; 邵婷婷; 刘昳; 刘华; 彭娟; 李程; 黄晓明; 邓志宏; 田磊; 赵慧; 姚勇; 文丹; 李中文; 易湘龙; 宋秀胜; 周盛; 赵玥; 温鑫; 袁晴; 石文卿; 李东芳; 廖萱; 强军;

【Author】 SHAO Yi;YANG Wenli;Expert Workgroup of Standard Operating Guidelines for Ocular Ultrasound Examination and Measurement(2024);Ophthalmic Imaging and Intelligent Medicine Branch Chinese Medicine Education Association;Ophthalmology Committee of International Association of Translational Medicine;Chinese Ophthalmic Imaging Study Groups;

【通讯作者】 邵毅;杨文利;

【机构】 《眼部超声可视化生物规范测量指南(2024)》专家组; 中国医药教育协会眼科影像与智能医疗分会及智能医学专委会; 国际转化医学会眼科学专委会; 中国眼科影像研究专家组; 南昌大学第一附属医院; 首都医科大学附属北京同仁医院; 内蒙古医科大学附属医院; 四川大学华西医院; 浙江大学医学院附属第二医院; 天津医科大学眼科医院; 南华大学附属第一医院; 中国人民解放军总医院; 首都医科大学附属北京朝阳医院; 暨南大学附属深圳市眼科医院; 武汉大学人民医院; 复旦大学附属眼耳鼻喉科医院; 深圳市眼科医院深圳市眼病防治研究所; 昆明医科大学第一附属医院; 中山大学中山眼科中心; 厦门大学附属第一医院; 中南大学湘雅医院; 中国标准化研究院; 温州医科大学附属眼视光医院; 福建中医药大学附属人民医院; 南京中医药大学附属南京市中医院; 锦州医科大学附属第三医院; 广州医科大学附属第二医院; 厦门大学眼科研究所; 四川眼科医院; 中南大学湘雅三医院; 上海交通大学医学院附属第一人民医院; 广州希玛林顺潮眼科医院; 温州医科大学附属宁波市眼科医院; 新疆医科大学第一附属医院; 恩施州中心医院; 中国医学科学院生物医学工程所; 南京医科大学附属眼科医院; 中山大学附属孙逸仙纪念医院; 九江市第一人民医院; 同济大学附属同济医院; 山东第一医科大学附属青岛眼科医院; 川北医学院附属医院; 沧州爱尔眼科医院;

【摘要】 超声检查和测量的准确性对眼部疾病的诊断有着重要意义。常用的眼超声检查主要包括A型超声、B型超声、超声生物显微镜(UBM)和彩色多普勒血流成像等方法。A型超声主要用于测量不同回声强度的组织之间的距离。B型超声可以显示眼的二维结构并对目标点进行定量测量。UBM是一种超高频的二维成像方法,可清晰显示眼前段的结构特点并测量相关参数,对房角形态改变的定量分析,眼内镜植入手术前、后的眼前段形态变化均可提供帮助。彩色多普勒血流成像在二维超声的基础上应用多普勒效应可定量测量移动物质的相关参数,反映眼局部的血流变化情况。为规范不同超声检查方法在眼部检查中的测量操作,特制定本指南。本指南主要针对不同类型眼部超声仪器测量的规范化操作及其在眼部疾病中的临床应用来进行阐述,从而为相关眼部疾病的诊断和治疗提供一定的指导意见。

【Abstract】 The accuracy of ultrasound examination and measurement is of great significance to diagnosing ocular diseases. The commonly used ocular ultrasonography includes amplitude(A)-mode ultrasound, brightness(B)-mode ultrasound, ultrasound biomicroscopy(UBM), and color Doppler flow imaging(CDFI). A-mode ultrasound is mainly used to measure the distance between tissues with different echo intensities. B-mode ultrasound can visualize the two-dimensional structure of the eye and make quantitative measurements of the target point. UBM is an ultra-high-frequency two-dimensional imaging method, which can clearly display the structural characteristics of the anterior segment and measure the relevant parameters. It can also help quantitatively analyze the morphological changes of the angle and the anterior segment before and after implantable collamer lens surgery. CDFI can quantitatively measure the parameters of blood vessels by applying the Doppler effect on the basis of two-dimensional ultrasound, reflecting the changes of blood flow in the eye. To standardize the operations of different ultrasound examination methods, this guideline is formulated. This guideline mainly focuses on the standardized operation of ocular ultrasound instruments and their clinical application in ocular diseases, so as to provide guidance for the diagnosis and treatment of related ocular diseases.

【基金】 国家自然科学基金(编号:82160195);江西省双千计划科技创新高端领军人才项目(编号:jxsq2023201036);江西省重大(重点)研发专项计划(编号:20223BBH80014);国家重点研发计划项目(编号:2018YFC0116000)
  • 【文献出处】 眼科新进展 ,Recent Advances in Ophthalmology , 编辑部邮箱 ,2024年06期
  • 【分类号】R770.4
  • 【下载频次】104