节点文献
火电机组灵活性技术改造热力特性试验研究
ExperimentalStudy on Thermal Characteristics of Thermal Power Unit Flexibility Technical Reform
【摘要】 供热机组进行灵活性改造,对其热力特性进行试验研究。结果表明,在供热工况平均供热负荷为327.86 MW(1180.31GJ/h)时,最小出力平均电负荷为97.88 MW,为机组额定出力的29.66%,锅炉最低蒸发量为447.44 t/h,未投燃油助燃,燃烧稳定;最大出力平均电负荷为310.75 MW,为机组额定出力的94.17%,锅炉最大蒸发量为976.27 t/h。纯凝工况最小出力平均电负荷为96.71 MW,为机组额定出力的29.31%,锅炉最低蒸发量为304.44 t/h,未投燃油助燃,燃烧稳定;最大出力平均电负荷为332.87 MW,为机组额定出力的100.87%,锅炉最低蒸发量为962.70 t/h。主汽、再热汽温度、压力满足汽机运行的需要。
【Abstract】 The thermal characteristics of the heating unit were tested and modified flexibly. Under the heating condition, the results showed that the average heating load was 327.86MW(1180.31GJ/h), the average electric load of the minimum output was 97.88MW, which was 29.66% of the rated output of the unit, and the minimum evaporation capacity of the boiler was 447.44t/h without fuel, combustion stability. The average electric load of the maximum output is 310.75MW, which is 94.17% of the rated output of the unit, and the maximum evaporation of the boiler is 976.27t/h. In the pure condensing condition, the average electric load of the minimum output under pure coagulation condition is 96.71MW, which is 29.31% of the rated output of the unit. The minimum evaporation of the boiler is 304.44t/h, and the combustion is stable without fuel injection. The average electric load of the maximum output is 332.87MW, which is 100.87% of the rated output of the unit, and the minimum evaporation capacity of the boiler is 962.70t/h. Main steam and reheat steam temperature and pressure meet the needs of steam engine operation.
【Key words】 thermal power units; new energy consumption; depth peak-load; flexibility transformation; thermal characteristics;
- 【文献出处】 电站系统工程 ,Power System Engineering , 编辑部邮箱 ,2024年06期
- 【分类号】TM621
- 【下载频次】63