节点文献

Cleaning of two mirrors in the first mirror unit using radiofrequency capacitively coupled plasma

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王晨雪鄢容刘玉明徐苏穆磊郑薇丁锐陈俊凌

【Author】 Chenxue WANG;Rong YAN;Yuming LIU;Su XU;Lei MU;Wei ZHENG;Rui DING;Junling CHEN;Institute of Plasma Physics, Chinese Academy of Sciences;University of Science and Technology of China;School of Computer Engineering, Anhui Sanlian University;

【通讯作者】 鄢容;穆磊;

【机构】 Institute of Plasma Physics, Chinese Academy of SciencesUniversity of Science and Technology of ChinaSchool of Computer Engineering, Anhui Sanlian University

【摘要】 First mirror(FM) cleaning, using radio frequency(RF) plasma, has been proposed to recover FM reflectivity in nuclear fusion reactors such as the International Thermonuclear Experimental Reactor(ITER). To investigate the influence of simultaneous cleaning of two mirrors on mirror cleaning efficiency and uniformity, experiments involving single-mirror cleaning and dualmirror cleaning were conducted using RF capacitively coupled plasma in the laboratory. For the test and simultaneous cleaning of two mirrors, the FM and second mirror(SM), both measuring110 mm × 80 mm, were placed inside the first mirror unit(FMU). They were composed of 16mirror samples, each with a dimension of 27.5 mm × 20 mm. These mirror samples consist of a titanium–zirconium–molybdenum alloy substrate, a 500 nm Mo intermediate layer and a 30 nm Al2O3 surface coating as a proxy for Be impurities. The cleaning of a single first mirror(SFM)and the simultaneous cleaning of the FM and SM(DFM and DSM) lasted for 9 h using Ar plasma at a pressure of 1 Pa. The total reflectivity of mirror samples on the DSM did not fully recover and varied with location, with a self-bias of-140 V. With a self-bias of-300 V, the total reflectivity of mirror samples on the SFM and DFM was fully recovered. The energy dispersive spectrometer results demonstrated that the Al2O3 coating had been completely removed from these mirror samples. However, the mass loss of each mirror sample on the SFM and DFM before and after cleaning varied depending on its location, with higher mass loss observed for mirror samples located in the corners and lower loss for those in the center.Compared with SM cleaning, the simultaneous cleaning of two mirrors reduced the difference between the highest and lowest mass loss. Furthermore, this mass loss for the mirror samples of the DFM facing the DSM was increased. This indicated that mirror samples cleaned face to face in the FMU simultaneously could influence each other, highlighting the need for special attention in future studies.

【Abstract】 First mirror(FM) cleaning, using radio frequency(RF) plasma, has been proposed to recover FM reflectivity in nuclear fusion reactors such as the International Thermonuclear Experimental Reactor(ITER). To investigate the influence of simultaneous cleaning of two mirrors on mirror cleaning efficiency and uniformity, experiments involving single-mirror cleaning and dualmirror cleaning were conducted using RF capacitively coupled plasma in the laboratory. For the test and simultaneous cleaning of two mirrors, the FM and second mirror(SM), both measuring110 mm × 80 mm, were placed inside the first mirror unit(FMU). They were composed of 16mirror samples, each with a dimension of 27.5 mm × 20 mm. These mirror samples consist of a titanium–zirconium–molybdenum alloy substrate, a 500 nm Mo intermediate layer and a 30 nm Al2O3 surface coating as a proxy for Be impurities. The cleaning of a single first mirror(SFM)and the simultaneous cleaning of the FM and SM(DFM and DSM) lasted for 9 h using Ar plasma at a pressure of 1 Pa. The total reflectivity of mirror samples on the DSM did not fully recover and varied with location, with a self-bias of-140 V. With a self-bias of-300 V, the total reflectivity of mirror samples on the SFM and DFM was fully recovered. The energy dispersive spectrometer results demonstrated that the Al2O3 coating had been completely removed from these mirror samples. However, the mass loss of each mirror sample on the SFM and DFM before and after cleaning varied depending on its location, with higher mass loss observed for mirror samples located in the corners and lower loss for those in the center.Compared with SM cleaning, the simultaneous cleaning of two mirrors reduced the difference between the highest and lowest mass loss. Furthermore, this mass loss for the mirror samples of the DFM facing the DSM was increased. This indicated that mirror samples cleaned face to face in the FMU simultaneously could influence each other, highlighting the need for special attention in future studies.

【基金】 supported by the National Key R&D Project of China (No. 2022YFE03030000);National Natural Science Foundation of China (Nos. 11975269, 12275306 and 12075279);the Youth Innovation Promotion Association of the Chinese Academy of Sciences (No. 2022452);the Anhui Provincial Natural Science Foundation (No. 2208085J40);the CASHIPS Director’s Fund (Nos. YZJJQY202302 and BJPY2023B03);the Comprehensive Research Facility for Fusion Technology Program of China (No. 2018-000052-73-01-001228)
  • 【文献出处】 Plasma Science and Technology ,等离子体科学和技术(英文版) , 编辑部邮箱 ,2024年09期
  • 【分类号】TL612
  • 【下载频次】2
节点文献中: 

本文链接的文献网络图示:

本文的引文网络