节点文献

A research on the effect of plasma spectrum collection device on LIBS spectral intensity

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 林晓梅董艳杰林京君黄玉涛杨江飞岳星宇张倬嘉段鑫杨

【Author】 Xiaomei LIN;Yanjie DONG;Jingjun LIN;Yutao HUANG;Jiangfei YANG;Xingyu YUE;Zhuojia ZHANG;Xinyang DUAN;Changchun University of Technology;

【通讯作者】 林京君;黄玉涛;

【机构】 Changchun University of Technology

【摘要】 Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information. To overcome this limitation, this study presents a novel method for acquiring plasma spectral information from various spatial directions. A parabolic-shaped plasma spectral collection device(PSCD) is employed to effectively collect more spectral information into the spectrometer,thereby enhancing the overall spectral intensity. The research objects in this study were soil samples containing different concentrations of heavy metals Pb, Cr, and Cd. The results indicate that the PSCD significantly enhances the spectral signal, with an enhancement rate of up to 45%. Moreover, the signal-to-noise ratio also increases by as much as 36%. Simultaneously,when compared to the absence of a device, it is found that there is no significant variation in plasma temperature when the PSCD is utilized. This observation eliminates the impact of the spatial effect caused by the PSCD on the spectral intensity. Consequently, a concentrationspectral intensity relationship curve is established under the PSCD. The results revealed that the linear fitting R~2 for Pb, Cr, and Cd increased by 0.011, 0.001, and 0.054, respectively. Additionally,the limit of detection(LOD) decreased by 0.361 ppm, 0.901 ppm, and 0.602 ppm, respectively.These findings indicate that the spectral enhancement rate elevates with the increase in heavy metal concentration. Hence, the PSCD can effectively enhance the spectral intensity and reduce the detection limit of heavy metals in soil.

【Abstract】 Only a small amount of spectral information is collected because the collection solid angle of the optical fiber probe and lens is very limited when collecting spectral information. To overcome this limitation, this study presents a novel method for acquiring plasma spectral information from various spatial directions. A parabolic-shaped plasma spectral collection device(PSCD) is employed to effectively collect more spectral information into the spectrometer,thereby enhancing the overall spectral intensity. The research objects in this study were soil samples containing different concentrations of heavy metals Pb, Cr, and Cd. The results indicate that the PSCD significantly enhances the spectral signal, with an enhancement rate of up to 45%. Moreover, the signal-to-noise ratio also increases by as much as 36%. Simultaneously,when compared to the absence of a device, it is found that there is no significant variation in plasma temperature when the PSCD is utilized. This observation eliminates the impact of the spatial effect caused by the PSCD on the spectral intensity. Consequently, a concentrationspectral intensity relationship curve is established under the PSCD. The results revealed that the linear fitting R~2 for Pb, Cr, and Cd increased by 0.011, 0.001, and 0.054, respectively. Additionally,the limit of detection(LOD) decreased by 0.361 ppm, 0.901 ppm, and 0.602 ppm, respectively.These findings indicate that the spectral enhancement rate elevates with the increase in heavy metal concentration. Hence, the PSCD can effectively enhance the spectral intensity and reduce the detection limit of heavy metals in soil.

【基金】 supported by Department of Science and Technology of Jilin Province of China (Nos. YDZJ202301 ZYTS481, 202202901032GX, and 20230402068GH)
  • 【文献出处】 Plasma Science and Technology ,等离子体科学和技术(英文版) , 编辑部邮箱 ,2024年05期
  • 【分类号】O657.38
  • 【下载频次】4
节点文献中: 

本文链接的文献网络图示:

本文的引文网络