【摘要】 A dual-route optical emission spectroscopy(D-OES) diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density ne and deuterium temperature TD in the X-point multifaceted asymmetric radiation from the edge(MARFE) region are derived simultaneously by fitting the measured Da shape.The density ne is observed to increase from ~8.7×1018 m-3 to~7.8 × 1019 m-3,and the temperature TD drops from ~14.4 eV to ~2.3 eV after the onset of MARFE in the discharge#38260.
【Abstract】 A dual-route optical emission spectroscopy(D-OES) diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density ne and deuterium temperature TD in the X-point multifaceted asymmetric radiation from the edge(MARFE) region are derived simultaneously by fitting the measured Da shape.The density ne is observed to increase from ~8.7×1018 m-3 to~7.8 × 1019 m-3,and the temperature TD drops from ~14.4 eV to ~2.3 eV after the onset of MARFE in the discharge#38260.
【Key words】 optical emission spectroscopy; Balmer series; tokamak;
- 【文献出处】 Plasma Science and Technology ,等离子体科学和技术(英文版) , 编辑部邮箱 ,2024年03期
- 【分类号】TL631.24