节点文献
考虑风速差异的风电场调频备用协调控制策略
Coordinated Control of Frequency-Regulation Reserve Capacity for Wind Farm Considering Wind Speed Difference
【摘要】 由于风资源分布的差异性,风电场内不同机组的减载备用能力不同。在预留减载备用时,风电场应考虑不同机组的减载备用能力差异。针对该问题,构建了双馈风机的可用调频容量模型,在此基础上,提出了考虑风速差异的风电场调频备用协调控制策略。该策略根据不同风速机组的可用调频容量差异协调风电场的调频资源,在满足备用容量的同时充分利用转子动能,通常仅需控制部分风机,简化系统复杂性。在DIgSILENT/PowerFactory中搭建了系统仿真模型,仿真结果表明所提策略使风电场内不同风速的机组协调配合,改善系统的频率调节能力,缓解同步机调频压力。
【Abstract】 Due to the difference of wind resource distribution, different units in the wind farm have different de-loading reserve capacity. When reserving de-loading reserve, the wind farm should consider the difference of de-loading reserve capacity of different units. In order to solve this problem, the available frequency-regulation capacity model of doubly-fed induction generator is constructed in this paper. According to this model, a coordinated control of frequency-regulation reserve capacity for wind farm considering wind speed difference is proposed. In this strategy, the frequency-regulation resources of wind farms are coordinated according to the differences of available frequency-regulation capacity of different wind turbines, and the kinetic energy of the rotor is fully utilized while the reserve capacity is satisfied. Usually, only part of the wind turbines are controlled, which simplifies the complexity of the control system. The system simulation model is built in DIgSILENT/PowerFactory. The simulation results show that the proposed strategy can coordinate the units with different wind speeds in the wind farm, improve the frequency-regulation capability of the system and alleviate the frequency-regulation pressure of the synchronous machine when load disturbance occurs.
【Key words】 doubly-fed induction generator; wind farm; available frequency-regulation capacity; coordinated control; active power allocation;
- 【文献出处】 电力建设 ,Electric Power Construction , 编辑部邮箱 ,2023年02期
- 【分类号】TM614;TP273
- 【下载频次】58