节点文献
连续雷电冲击下典型杆塔接地装置冲击接地电阻分析
Impulse grounding resistance analysis of typical tower grounding device under continuous lightning impulse
【摘要】 为分析连续雷电冲击下杆塔接地装置的冲击特性,对不同土壤、材料及形状的典型接地体进行连续冲击试验。在连续脉冲冲击下,随着冲击脉冲时间间隔的增大,二次冲击接地电阻由土壤击穿时的较低值增大,逐渐恢复到单脉冲冲击接地电阻;但在一定的时间间隔范围内,含水量较少的土壤中接地装置的二次冲击接地电阻明显大于单脉冲冲击接地电阻;不同形状及不同材料接地体的二次冲击接地电阻不同。在杆塔接地设计时应考虑连续雷电冲击下冲击接地电阻增大现象,综合考虑接地体的材料及其形状。基于实验结果,提出连续雷电冲击下杆塔接地系统的ATPDraw仿真建模方法,该方法能较好地模拟冲击接地火花效应和土壤击穿后土壤电阻率恢复过程。
【Abstract】 In order to analyze the impulse characteristics of tower grounding device under continuous lightning impulse,continuous impact tests of typical grounding bodies with different soils,materials and shapes are carried out. Under continuous pulse impact,with the increase of impulse time interval,the secondary impact grounding resistance increases from the lower value at soil breakdown to the single pulse impact grounding resistance. However,within a certain time interval,the secondary impulse grounding resistance of grounding device in soil with less water content is significantly greater than that of single pulse impulse. The secondary impulse grounding resistances of grounding bodies with different shapes and materials are different. In the tower grounding design,the increase of impulse grounding resistance under continuous lightning impulse needs to be considered, and the material and shape of grounding body should be comprehensively considered. Based on the experimental results,the ATP Draw simulation modeling method of tower grounding system under continuous lightning impulse is proposed. This method achieves good effect when simulating the spark effect of impulse grounding and the recovery process of soil resistivity after soil breakdown.
【Key words】 continuous lightning impulse; tower grounding; impulse grounding resistance; soil resistivity;
- 【文献出处】 电力科学与技术学报 ,Journal of Electric Power Science and Technology , 编辑部邮箱 ,2023年01期
- 【分类号】TM862;TM75
- 【下载频次】23