节点文献

凝血检验自动审核问题与对策

Problems and solutions on autoverification of coagulation test

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 范庆坤李玲杜佳杨军张真路

【Author】 FAN Qingkun;LI Ling;DU Jia;YANG Jun;ZHANG Zhenlu;Department of Clinical Laboratory,Wuhan Asia Heart Hospital;

【通讯作者】 张真路;

【机构】 武汉亚洲心脏病医院检验医学中心

【摘要】 检验报告自动审核可显著缩短实验室内样本周转时间,提高工作效率,是检验科未来发展的趋势。凝血试验自动审核常面临不合格样本识别难、自动审核规则设计复杂等诸多问题。严格、规范的分析前质量控制和信息系统互联互通是实施凝血试验自动审核的基础。实验室应根据自身条件设定合适的凝血试验自动审核规则,以结果准确为前提,并持续优化,逐步提高检验报告自动审核通过率。

【Abstract】 The autoverification of reports is the future development trend of clinical laboratories,which can significantly shorten the laboratory sample turn-around time and improve work efficiency. The autoverification of coagulation tests is less used in clinical laboratories,due to many problems such as the identification of unqualified samples and the complex rules of autoverification. The basis for the implementation of autoverification is strict and standardized quality control of pre-analysis and interconnection of information systems. Based on the premise of accurate results,clinical laboratories can set appropriate autoverification rules according to its own conditions,continuously optimize the autoverification rules for coagulation test,and gradually increase the autoverification pass rate of clinical laboratory test.