节点文献

矿用轴流通风机集流区域主动降噪试验

Experimental Study on Active Noise Control in Intake Area of Mine Axial Fan

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 于琦王海桥刘刚张任强陈方兴陈永平旷颖仑

【Author】 YU Qi;WANG Haiqiao;LIU Gang;ZHANG Renqiang;CHEN Fangxing;CHEN Yongping;KUANG Yinglun;School of Resources, Environment and Safety Engineering, Hunan University of Science and Technology;Intelligent Manufacturing College, Hunan Vocational Institute of Technology;Hunan Mine Ventilation and Dust removal Equipment Engineering Technology Research Center, Hunan University of Science and Technology;Department of Energy Engineering and Building Environment,Guilin University of Aerospace Technology;Xiangtan Bureau of Ecology and Environment;

【通讯作者】 王海桥;

【机构】 湖南科技大学资源环境与安全工程学院湖南理工职业技术学院智能制造学院湖南科技大学湖南省矿山通风与除尘装备工程技术研究中心桂林航天工业学院能源与建筑环境学院湘潭市生态环境局

【摘要】 针对轴流通风机进行主动降噪,尚属于轴流通风机降噪领域的前沿问题.围绕该问题,以YBT-5.5型轴流通风机为试验对象,选取自由空间、对称分布受限空间、近壁面受限空间作为通风机试验环境,分析通风机集流区域的噪声分布,并对比了降噪前后的声压级、频谱特性.结果表明,集流区域正对方向,在自由空间下,降噪量可达7.2 dB(A);受限空间下,空间对称分布时降噪量为5.9 dB(A),近壁面处降噪量为2.8 dB(A).在通风机集流区域,对于斜向45°的测点,左侧降噪难度高于右侧;相较两侧的测点,左侧降噪难度低于右侧.当通风机位置从自由空间变为受限空间时,集流区域的噪声能量变化集中在100~500 Hz.

【Abstract】 The research is about active noise control of axial flow fans, which is a frontier issue in the field of noise reduction of axial flow fans. In order to study this problem, the YBT-5.5 axial flow fan is used as the experiment object. Free space, restricted space with symmetrical distribution, and restricted space near the wall are selected as the noise measurement environment of the fan. The noise distribution of the fan intake area is analyzed, and the sound pressure level and frequency spectrum characteristics before and after noise reduction are compared. The data show that in the opposite direction of the intake area, in free space, the noise reduction can reach 7.2 dB(A). In the confined space, the noise reduction is 5.9 dB(A) when the space is symmetrically distributed, and the noise reduction near the wall is 2.8 dB(A). For the measuring points with an oblique angle of 45°, the noise reduction difficulty on the left side is higher than that on the right side. For the measurement points on both sides, the noise reduction difficulty of the left side is lower than that of the right side. When the fan location changes from free space to confined space, the noise energy change in the intake area is concentrated in the range of 100~500 Hz.

【基金】 国家自然科学基金资助项目(51864014);交通运输部交通运输行业重点科技项目清单(2021-MS5-126);广西交通运输行业重点科技项目清单(桂交便函[2021]148号18);湖南省自然科学基金资助项目
  • 【文献出处】 矿业工程研究 ,Mineral Engineering Research , 编辑部邮箱 ,2022年04期
  • 【分类号】TD441.2
  • 【下载频次】15
节点文献中: 

本文链接的文献网络图示:

本文的引文网络