节点文献
盐酸莫西沙星片在中国健康受试者的生物等效性研究
Bioequivalence of moxifloxacin hydrochloride tablets in healthy Chinese subjects
【摘要】 目的:研究空腹及餐后单剂量口服盐酸莫西沙星片的药代动力学特征,并以Bayer Pharma AG生产的盐酸莫西沙星片作为参比制剂,比较二者的药动学参数,评价两制剂的人体生物等效性。方法:采用单中心、随机、开放、两周期、自身交叉的设计,空腹和餐后给药生物等效性研究各纳入23例健康受试者,每周期单次口服受试制剂或参比制剂0.4 g,采取HPLC-MS/MS法测定给药后不同时间点莫西沙星的血药浓度,计算主要药代动力学参数,评价受试制剂相对于参比制剂的相对生物利用度及生物等效性。结果:空腹组受试者服用受试制剂T和参比制剂R后,莫西沙星的主要药代动力学参数为:Cmax(3 476.0±855.2),(3 632.6±1 011.3)ng/mL;Tmax 1.50(0.25,4.00),2.50(0.25,4.00)h; AUC0-t(54 972.81±11 400.81),(56 757.41±12 670.53)h·ng·mL-1;AUC0-∞(56 791.17±11 681.08),(58 574.37±13 072.17)h·ng·mL-1;T1/2(14.13±2.40),(13.85±2.44)h。餐后组受试者服用受试制剂T和参比制剂R后,盐酸莫西沙星的主要药代动力学参数为:Cmax(3 744.3±819.2),(3 569.1±653.8)ng/mL;Tmax 1.50(0.50,4.00),1.50(0.50,4.00)h; AUC0-t(51 613.98±10 725.93),(52 322.70±10 189.50)h·ng·mL-1;AUC0-∞(53 585.13±10 954.51),(54 207.13±10 313.28)h·ng·mL-1;T1/2(14.47±3.71),(14.53±3.04)h。空腹组和餐后组的Cmax、AUC0-t、AUC0-∞几何均数比值90%CI均落在80.00%~125.00%之间。结论:空腹和餐后状态下受试制剂T与参比制剂R(拜复乐?)具有生物等效性且安全性良好。
【Abstract】 AIM: To study the pharmacokinetic characteristics of single-dose oral moxifloxacin hydrochloride tablets under fasting and fed conditions, and use moxifloxacin hydrochloride tablets produced by Bayer Pharma AG as a reference to compare the pharmacokinetic parameters of the two preparations, and evaluate the human bioequivalence of the two preparations. METHODS: A single-center, randomized, open, two-period, and self-crossover design was adopted to conduct a fasting and fed bioequivalence study of 23 healthy subjects each. The 0.4 g dose preparations were taken orally per cycle on fasting or fed administration. The plasma concentrations of moxifloxacin at different times after administration were determined by HPLC-MS/MS. The main pharmacokinetic parameters were calculated, and the bioavailability of the test preparation relative to the reference preparation was evaluated. RESULTS: After subjects in the fasting group took the test preparation T and the reference preparation R, the main pharmacokinetic parameters of moxifloxacin hydrochloride were: Cmax(3 476.0±855.2),(3 632.6±1 011.3) ng/mL; Tmax 1.50(0.25, 4.00), 2.50(0.25, 4.00) h; AUC0-t(54 972.81±11 400.81),(56 757.41±12 670.53) h·ng·mL-1; AUC0-∞(56 791.17±11 681.08),(58 574.37±13 072.17) h·ng·mL-1; T1/2(14.13±2.40),(13.85±2.44) h. After the subjects in the fed group took the test parameter T and the reference parameter R, the main pharmacokinetic parameters of moxifloxacin hydrochloride were: Cmax(3 744.3±819.2),(3 569.1±653.8) ng/mL; Tmax 1.50(0.50, 4.00), 1.50(0.50, 4.00) h; AUC0-t(51 613.98±10 725.93),(52 322.70±10 189.50) h·ng·mL-1; AUC0-∞(53 585.13±10 954.51),(54 207.13±10 313.28) h·ng·mL-1; T1/2(14.47±3.71),(14.53±3.04) h. The 90%CI of Cmax, AUC0-t, AUC0-∞ geometric mean ratios of the fasting group and the fed group all fell between 80.00%-125.00%. CONCLUSION: The test preparation T and the reference preparation R under fasting and fed conditions are bioequivalent and safe.
【Key words】 moxifloxacin hydrochloride; bioequivalence; pharmacokinetics; HPLC-MS/MS;
- 【文献出处】 中国临床药理学与治疗学 ,Chinese Journal of Clinical Pharmacology and Therapeutics , 编辑部邮箱 ,2021年12期
- 【分类号】R969.1
- 【下载频次】196